Max temperature excursion and fault trigger time are now configurable via M570 If a heater fault occurs then any SD card print in progress is abandoned Improved M122 diagnostics headings Bug fix: some values of pressure advance caused too many extruder steps to be schedules, resulting in extruder step errors, and another bug in the error handling then caused layer shifts