This repository has been archived on 2025-02-01. You can view files and clone it, but cannot push or open issues or pull requests.
reprapfirmware-dc42/Release/Duet-0.6-0.8.5
David Crocker bc8c679e46 Version 1.15e
Max temperature excursion and fault trigger time are now configurable
via M570
If a heater fault occurs then any SD card print in progress is abandoned
Improved M122 diagnostics headings
Bug fix: some values of pressure advance caused too many extruder steps
to be schedules, resulting in extruder step errors, and another bug in
the error handling then caused layer shifts
2016-10-02 11:13:27 +01:00
..
DuetWebControl-1.12.zip Updated to DWC 1.12 release 2016-08-24 08:24:42 +01:00
README Update README 2016-08-24 09:45:03 +01:00
RepRapFirmware-1.10+4-dc42.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.11-dc42.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.12-dc42.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.12a-dc42.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.13a.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.13b.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.14.bin Updated gitignore again 2016-08-23 21:40:54 +01:00
RepRapFirmware-1.15d.bin Added 1.15d binary for wired Duets 2016-09-25 14:47:42 +01:00
RepRapFirmware-1.15e.bin Version 1.15e 2016-10-02 11:13:27 +01:00

RepRapFirmware 1.15 release notes
===================================
1. If you are upgrading from a previous releases other than a 1.15 release candidate, then if you have any M301 commands in your config.g file, you should double the I parameters and halve the D parameters in those commands. This is because of a long-standing bug in previous releases of RepRapFirmware which has been corrected in this release.
2. This release includes a heater control auto tuning feature. See https://duet3d.com/wiki/Tuning_the_heater_temperature_control for how to use it. This feature is still somewhat experimental and will be refined in a future release.
3. The temperature monitoring is much more strict compared to previous releases, to better detect situations such as a thermistor or heater cartridge falling out of the heater block, which can pose a fire risk if not detected. If you have a paricularly strong or weak heater, you may get false alarms. The simplest way to avoid this is to run auto tuning so that the firmware can build a more accurate model of normal behaviour.
4. DuetWebControl-1.12.zip is by Christian Hammacher and is provided here for your convenence. His master repository is at https://github.com/chrishamm/DuetWebControl.