Commit graph

11 commits

Author SHA1 Message Date
David Crocker
fe7f857b78 Version 1.16beta3
Added stub for DueX5 support
Fixed bugs with homing and position reporting of U,V,W axes
2016-10-21 11:33:55 +01:00
David Crocker
ef4f962afa Version 1.16 beta 2
Implemented X axis set and report mapping in M563 command and in web and
M408 status responses (but mapping doesn;t do anything yet)
Report number of axes to DWC
M307 H# A-1 C-1 D-1 disables the pid controller for that heater to free
up the pin
Debug print of matrixes during delta calibration is now to 4dp
Implemented fan blip
2016-10-19 15:30:41 +01:00
David Crocker
62948df9b5 Added 1.16 alpha 1 binary 2016-10-16 22:08:41 +01:00
David Crocker
bc8c679e46 Version 1.15e
Max temperature excursion and fault trigger time are now configurable
via M570
If a heater fault occurs then any SD card print in progress is abandoned
Improved M122 diagnostics headings
Bug fix: some values of pressure advance caused too many extruder steps
to be schedules, resulting in extruder step errors, and another bug in
the error handling then caused layer shifts
2016-10-02 11:13:27 +01:00
David Crocker
6639d21e51 Release 1.15d
Changes to reduce incidence of false heating fault alarms, in particular
"temperature rising much more slowly than the expected 0.0C"
Stepper drivers beyond the first 5 are assumes to be non-TMC2660 drivers
2016-09-25 11:15:54 +01:00
David Crocker
caed54112c Version 1.15c
Increased max number of probe points to 64 on Duet WiFi and 32 on Duet
0.6/0.8.5
Corrected M37 reporting of simulation time
Added move debug facility
Added recording of more types of move underrun
Use fabsf instead of fabs
M21 doesn't re-mounjt a drive that is aloready mounted and has open
files on it
Added "volumes" variable in extended status report
Report card details after M21 is called
Bug fix: M220 speed changes were nott being implemented as soon as they
should be
Bug fix: lookahead was sometimes failing to join sequences of short
decelerating moves together
Bug fix: at startup the thermistor readings were sometimes very high,
which triggered a bug in strtod() called in PanelDue firmware 1.14 and
earlier
2016-09-06 22:17:38 +01:00
David Crocker
a79a91721b Version 1.15b
Fixed problem that sometimes caused temperatures to creep up when using
legacy PID parameters
2016-08-25 20:54:30 +01:00
dc42
5b1cd82404 Update README.md 2016-08-24 09:45:31 +01:00
dc42
61d52c8d36 Create README.md 2016-08-24 09:40:46 +01:00
David Crocker
95fbdd263f Updated to DWC 1.12 release 2016-08-24 08:24:42 +01:00
David Crocker
d5b99bea9b Updated gitignore again 2016-08-23 21:40:54 +01:00