- Added support for M374 (save height map) and M375 (load height map)
- Added M376 (set bed compensation taper height)
- Added T parameter to G31 command
- M500, M501 and M502 now use config_override.g instead of flash memory.
The parameters saved and restored are:
-- M307 auto tune results
-- PID parameters, if you used M301 to override the auto tune PID
settings
-- Delta printer M665 and M666 settings
-- G31 trigger height, trigger value and X and Y offsets
- The M501 auto save option has been removed
- Removed S and T parameters from M301 command. Use M307 command
instead.
- M301 with negative P parameter no longer sets bang-bang mode. Use M307
instead.
- Added P parameter to the G31 command to specify Z probe type. This
allows you to view the parameters for the Z probe(s) and to set
parameters for a particular Z probe type without selecting that type.
G31 P or G31 P0 prints the parameters of the currently-selected Z probe.
- Z probe offsets are now applied during G30 probing with specified XY
coordinates, including during delta auto calibration
- Z probe recovery time is now applied from the end of the travel move
just before probing
- Fixed bad dive height when using G29 with a large trigger height
- Fixed bad JSON message during printing when there were no active
extruders
- Added exception handlers and store a software reset code when an
exception occurs
- Fixed reset reason text because on the Duet WiFi a watchdog reset can
look like an external reset
- G30 S-1 how printes the stopped height
- Implemented M401 and M402
Support up to 6 axes in many commands
Allow creation of additional axes in M584
Display delta paremners to 3dp instead of 2dp
Removed M126/M127 error messages
Delta calibration now supports bed tilt parameters
On Duet WiFi, delta calibration is now done in double precision maths
Added support for G4 S parameter
Bed compensation or delta calibration is now aborted if the probe was
triggered at the start or was not triggered by the end of the probing
move
Bug fix: JSON file list returned by M20 S2 is now terminated by \n
Bug fix: stupidly high temperatures were returned immediately after
power up in response to status requests
Bug fix: when using an analog Z probe, probing movements were sometimes
aborted before the full depth had been probed but the firmware thought
that probing had terminated at the full depth
Bug fix: generic messages were sent to PanelDue in plain text format
Fixed doubling of M301 I parameter and halving of M301 P parameter
Implemented M303 auto tune and M307 heater process model
Improved temperature monitoring to detect heater cartridges or
thermistor falling out
Implemented M38 (thanks chrishamm)
Retructured course code tree