David Crocker
df5507c8c8 More work on Duet Ethernet support 2016-12-23 23:19:33 +00:00
David Crocker
fdcef50706 Version 1.17RC3
Bed compensation taper is now applied to 3/4/5-point compensation
methods too
Recognise generated-with comment in new Cura gcode files
Recognise filament-used info min new kisslicer files
When uploading files, create the full path if necessary
Duet 0.8.5 webserver looks for gzipped files first
A second controlled fan on the Duet 0.6 is no longer inverted
2016-12-21 17:17:57 +00:00
David Crocker
90c4e1a53a Version 1.17RC2
Renamed function Network::IPAddress to GetIPAddress to avoid clash with
IPAddress class used in DuetEthernet build
Duet 0.8.5 web server now looks for a gzipped version of the file is a
web file was not found
Duet 0.8.5 web server only returns a 404 page of the file that was not
found was a .html or .htm file
2016-12-18 15:46:03 +00:00
David Crocker
da3d67403f 1.17RC1+2
Changes for Duet Ethernet
Changes RADDS Pins.h to support 2 SD cards
2016-12-17 16:58:27 +00:00
David Crocker
d978aa57a6 Version 1.17rc1a
Restructured directories and dded build configuration for Duet Ethernet
2016-12-13 21:32:10 +00:00
David Crocker
cd5af6c7b1 Version 1.17rc1
- Added support for M374 (save height map) and M375 (load height map)
- Added M376 (set bed compensation taper height)
- Added T parameter to G31 command
- M500, M501 and M502 now use config_override.g instead of flash memory.
The parameters saved and restored are:
-- M307 auto tune results
-- PID parameters, if you used M301 to override the auto tune PID
settings
-- Delta printer M665 and M666 settings
-- G31 trigger height, trigger value and X and Y offsets
- The M501 auto save option has been removed
- Removed S and T parameters from M301 command. Use M307 command
instead.
- M301 with negative P parameter no longer sets bang-bang mode. Use M307
instead.
- Added P parameter to the G31 command to specify Z probe type. This
allows you to view the parameters for the Z probe(s) and to set
parameters for a particular Z probe type without selecting that type.
G31 P or G31 P0 prints the parameters of the currently-selected Z probe.
- Z probe offsets are now applied during G30 probing with specified XY
coordinates, including during delta auto calibration
- Z probe recovery time is now applied from the end of the travel move
just before probing
- Fixed bad dive height when using G29 with a large trigger height
- Fixed bad JSON message during printing when there were no active
extruders
- Added exception handlers and store a software reset code when an
exception occurs
- Fixed reset reason text because on the Duet WiFi a watchdog reset can
look like an external reset
- G30 S-1 how printes the stopped height
- Implemented M401 and M402
2016-12-12 15:27:39 +00:00
David Crocker
88e3092b78 Version 1.17 dev 4
Support concurrenrt execution of commands form different channels
M143 now supports individual temperature limits per heater
Fixed issue with dely of up to 2 seconds when switching Duet WiFi heater
channel 3 to servo mode
When enable polarity is set using the M569 R parameter, disable the
corresponding drive
Add exdperimental S99 option on G1 command to log probe changes (Duet
WiFi only)
2016-11-17 21:29:20 +00:00
David Crocker
35a9a1a707 Version 1.17-dev1
Support R and S parameters in M109 and M190 as Marlin does
Added support for M191
Added support for Steinhart-Hart C parameter
Thermistor disconnected threshold now depends on thermistor parameters
2016-11-12 18:40:28 +00:00
David Crocker
0e80563905 Version 1.16 release
Added I parameter in M280 command
Added diagnostic test (M122 S101) for SX1509B chip on Duet WiFi
expansion boards
Heaters driven from TC channels on Duet WiFi no longer glitch on for a
short while after reset
Bug fix: M280 S-1 was ignoring inverted output status
Bug fix: if there were too many files in the /gcodes folder then AJAX
errors occurred (thanks chrishamm)
2016-11-08 16:21:43 +00:00
David Crocker
619e5c489f Version 1.16rc2
Fixed several bugs in file time stamping
Fixed M280 and M42 commands using unused heaster channels on Duet 0.6
and 0.8.5
Reduced the amount of I2C traffic, by using DueX5 interrupt line to tell
if new data is available and by only sending fan PWM values when they
change
Display TMC2660 driver status and DueX2/X5 stall status in M122 response
Removed E parameter from M574 command (use M558 I parameter instead)
Fixed response to M307 with H parameter only
2016-11-05 20:01:02 +00:00
David Crocker
fcbf543a18 Version 1.16rc1
Merged in chrishamm's changes to support tmie stamping of uploaded files
(thanks chrishamm)
Added fan mapping in M563 command
2016-11-03 16:52:11 +00:00
David Crocker
4d6a7f49f5 Version 1.16 beta 10
Added DueX2/DueX5 support
Report expansion board type in electronics string
Added Z probe type 6 (switch on E1 stop)
Support heater 6 on Duet 0.8.5 (untested, probably incomplete)
Changed M42 pin numbering, see duet3d.com wiki
Added M280 servo support
Allow separate firmware un-retract speed to be configured in M207
Allow negative extra un-retraction in M207
Allow dans ot be disabled yusing M106 P# I-1. They can then be used as
general-purpose pins (m42) or servos (M280).
Removed support for Duet WiFi prototype 1 board
Support expanson pin PB6 and use it for cooling fan tacho
2016-10-28 19:56:24 +01:00
David Crocker
fe7f857b78 Version 1.16beta3
Added stub for DueX5 support
Fixed bugs with homing and position reporting of U,V,W axes
2016-10-21 11:33:55 +01:00
David Crocker
ef4f962afa Version 1.16 beta 2
Implemented X axis set and report mapping in M563 command and in web and
M408 status responses (but mapping doesn;t do anything yet)
Report number of axes to DWC
M307 H# A-1 C-1 D-1 disables the pid controller for that heater to free
up the pin
Debug print of matrixes during delta calibration is now to 4dp
Implemented fan blip
2016-10-19 15:30:41 +01:00
David Crocker
d89ec70dfc Version 1.16 beta 1 (more like an alpha)
Support up to 6 axes in many commands
Allow creation of additional axes in M584
Display delta paremners to 3dp instead of 2dp
Removed M126/M127 error messages
Delta calibration now supports bed tilt parameters
On Duet WiFi, delta calibration is now done in double precision maths
Added support for G4 S parameter
Bed compensation or delta calibration is now aborted if the probe was
triggered at the start or was not triggered by the end of the probing
move
Bug fix: JSON file list returned by M20 S2 is now terminated by \n
Bug fix: stupidly high temperatures were returned immediately after
power up in response to status requests
Bug fix: when using an analog Z probe, probing movements were sometimes
aborted  before the full depth had been probed but the firmware thought
that probing had terminated at the full depth
Bug fix: generic messages were sent to PanelDue in plain text format
2016-10-16 22:07:10 +01:00
David Crocker
bc8c679e46 Version 1.15e
Max temperature excursion and fault trigger time are now configurable
via M570
If a heater fault occurs then any SD card print in progress is abandoned
Improved M122 diagnostics headings
Bug fix: some values of pressure advance caused too many extruder steps
to be schedules, resulting in extruder step errors, and another bug in
the error handling then caused layer shifts
2016-10-02 11:13:27 +01:00
David Crocker
6639d21e51 Release 1.15d
Changes to reduce incidence of false heating fault alarms, in particular
"temperature rising much more slowly than the expected 0.0C"
Stepper drivers beyond the first 5 are assumes to be non-TMC2660 drivers
2016-09-25 11:15:54 +01:00
David Crocker
658cfc8923 Version 1.15 release
Relocated heater 7 to correrct pin on Duet WiFi
Fixed thermistor reading startup issues
Added over/under voltage count on Duet WiFi
2016-08-23 21:28:28 +01:00
David Crocker
ed40658c45 Version 1.15rc2
Fixed doubling of M301 I parameter and halving of M301 P parameter
Implemented M303 auto tune and M307 heater process model
Improved temperature monitoring to detect heater cartridges or
thermistor falling out
Implemented M38 (thanks chrishamm)
Retructured course code tree
2016-08-20 12:14:28 +01:00
David Crocker
4bca2a787b Version 1.15 beta 6
Add support for second SD card on SPI bus for Duet WiFi including
implementation of M21 and M22
New temperature monitoring
Increased PWM resolution
When uploading files to wifi module, skip empty blocks
Revised TMC driver in preparation for standstill current reduction
Fixed PrintMonitor bug when the slicer comment includes a '\' character
2016-08-10 15:24:14 +01:00
David Crocker
58a7aa11d8 Release 1.15 beta 3
Further optimisation of step generation ISR
Don't allow more than half the capacity of the DDA queue to be frozen
Duet WiFi: print additional info from WiFi module
2016-07-16 08:21:19 +01:00
David Crocker
1ac43b3bf2 Version 1.14
- Fix for uncommanded stepper motor movement on some systems following a
software reset
- When multiple motors are due to step, generate all the step pulses
simultaneously
- Added support for multiple drivers for a single axis (M584)
- Added support for extended step pulse width when using external
drivers (T parameter on M569 command)
- Removed XYZE params from M569 (use M584 instead)
- Added M913 command (set motor % of normal current)
- Added Z probe type 5, which is a normally-closed switch or active-high
probe connected to the Z probe connector
- Duet WiFi default Z probe threshold is now 500
- Duet WiFi defaults to using a low end homing switch on the X axis
2016-07-02 17:21:16 +01:00
David Crocker
f7cff3a054 Version 1.14 very early beta
Changes to use new pin modes in CoreNG
Initialise TMC2660 step/dir/CS pins as early as possible
Allow emergency stop in simulation mode
Disable drives and heaters when doing a software reset
Support 10th drive and 8th heater on Duet WiFi
TMC2660 driver support is now only in Duet WiFi firmware build
2016-06-28 21:50:13 +01:00
David Crocker
ac4794daf1 Version 1.13a
Fixed thermostatic fan bug introduced in version 1.13
Added MCU temperature monitoring
Duet WiFi only: added voltage monitoring, and disable TMC2660 drivers if
the voltage is too low or too high. Not tested as at time of this
checkin,
2016-06-19 23:39:25 +01:00
David Crocker
b12a131e28 Version 1.13
Temporary fix for RTD temperature spikes causing failed prints
Added 'only if printing a file' condition in M581 command
Fixed M117 for PanelDue
Don't print extruder positions in M114 because they are always zero
Process M0 and M1 when in simulation mode
Allow setting of fan PWM from 50% upwards when a fan is in thermostatic
mode
Reduced default extruder heater PWM frequency
Axes are no longer homes when microstepping is changed
SD card interface speed is included in M122 output
2016-06-15 21:47:15 +01:00