1. Z-probing is now done in two stages: a fast stage at the configured
home feed rate until within 10% of the target value, then a slow stage
at 20% of that feed rate.
2. Provisional support for ultrasonic Z-probe.
3. Added calibration temperature and height temperature coefficient to Z
probe parameters.
4. Z-probe parameters and Z-probe type are now saved to flash memory so
that they survive power-off and reset cycles. Separate parameters are
retained for IR and ultrasonic probes in case both are fitted.
5. Fixed issue with doing slow Z-moves immediately after Z-homing or
probing.
Increase TCP window size from 1 to 2 packets and increase maximum amount
of web data sent to 1460. This decreases the page load time fro a
Windows client fro 6 seconds to less than 1 second. It also fixes a
problem whereby when using a Ubuntu client, file upload and direct print
didn't work unless the reprap.js file was edited to reduce the maximum
amount of data sent per request. Also we now initialize unused memory
with known data so that in response to the M111 S1 command we can better
estimate the amount of free memory.
Increase incoming web gcode buffer size to 1200 chars to allow more
gcodes to be sent in each message
Include free buffer size in poll response
Include response sequence number in poll response
Implement M30 (delete file) via USB interface
Support M503 and M111 commands via web interface
Added new fields "zprobe" and "resp" to webserver poll response
Immutable string parameters are passed as const char* not char*
Increase max number of files displayed to 42
Range-check heater parameters in incoming commands to avoid buffer
overflow if heater number is out of range
Improved network error recovery so that it it possible to reconnect
after some types of network error have occurred
Corrected calculation of temperatures to give more accurate results
towards the limits of the ADC range