Commit graph

16 commits

Author SHA1 Message Date
David Crocker
4d6a7f49f5 Version 1.16 beta 10
Added DueX2/DueX5 support
Report expansion board type in electronics string
Added Z probe type 6 (switch on E1 stop)
Support heater 6 on Duet 0.8.5 (untested, probably incomplete)
Changed M42 pin numbering, see duet3d.com wiki
Added M280 servo support
Allow separate firmware un-retract speed to be configured in M207
Allow negative extra un-retraction in M207
Allow dans ot be disabled yusing M106 P# I-1. They can then be used as
general-purpose pins (m42) or servos (M280).
Removed support for Duet WiFi prototype 1 board
Support expanson pin PB6 and use it for cooling fan tacho
2016-10-28 19:56:24 +01:00
David Crocker
ef4f962afa Version 1.16 beta 2
Implemented X axis set and report mapping in M563 command and in web and
M408 status responses (but mapping doesn;t do anything yet)
Report number of axes to DWC
M307 H# A-1 C-1 D-1 disables the pid controller for that heater to free
up the pin
Debug print of matrixes during delta calibration is now to 4dp
Implemented fan blip
2016-10-19 15:30:41 +01:00
David Crocker
bc8c679e46 Version 1.15e
Max temperature excursion and fault trigger time are now configurable
via M570
If a heater fault occurs then any SD card print in progress is abandoned
Improved M122 diagnostics headings
Bug fix: some values of pressure advance caused too many extruder steps
to be schedules, resulting in extruder step errors, and another bug in
the error handling then caused layer shifts
2016-10-02 11:13:27 +01:00
David Crocker
ed40658c45 Version 1.15rc2
Fixed doubling of M301 I parameter and halving of M301 P parameter
Implemented M303 auto tune and M307 heater process model
Improved temperature monitoring to detect heater cartridges or
thermistor falling out
Implemented M38 (thanks chrishamm)
Retructured course code tree
2016-08-20 12:14:28 +01:00
David Crocker
4bca2a787b Version 1.15 beta 6
Add support for second SD card on SPI bus for Duet WiFi including
implementation of M21 and M22
New temperature monitoring
Increased PWM resolution
When uploading files to wifi module, skip empty blocks
Revised TMC driver in preparation for standstill current reduction
Fixed PrintMonitor bug when the slicer comment includes a '\' character
2016-08-10 15:24:14 +01:00
David Crocker
1ac43b3bf2 Version 1.14
- Fix for uncommanded stepper motor movement on some systems following a
software reset
- When multiple motors are due to step, generate all the step pulses
simultaneously
- Added support for multiple drivers for a single axis (M584)
- Added support for extended step pulse width when using external
drivers (T parameter on M569 command)
- Removed XYZE params from M569 (use M584 instead)
- Added M913 command (set motor % of normal current)
- Added Z probe type 5, which is a normally-closed switch or active-high
probe connected to the Z probe connector
- Duet WiFi default Z probe threshold is now 500
- Duet WiFi defaults to using a low end homing switch on the X axis
2016-07-02 17:21:16 +01:00
David Crocker
f7cff3a054 Version 1.14 very early beta
Changes to use new pin modes in CoreNG
Initialise TMC2660 step/dir/CS pins as early as possible
Allow emergency stop in simulation mode
Disable drives and heaters when doing a software reset
Support 10th drive and 8th heater on Duet WiFi
TMC2660 driver support is now only in Duet WiFi firmware build
2016-06-28 21:50:13 +01:00
David Crocker
eb5445770b Version 1.13 beta 1
Added support for M581 and M582 commands
M25 pause command can now be used inside a macro file to pause a file
being printed from SD card
Firmware update messages are now sent to USB and PanelDue (but the
existing PanelDue firmware doesn't display them)
Added gcode queue underrun counter, displayed in M122 Move diagnostic
info
M122 responses are now sent only to the comms channel that requested
them
Added support for additional firmware modules to be updated for Duet NG
Corrected a possible problem with multiple incompatible gcodes being
executed concurrently
Support H parameter on M0 and M1 commands
When executing M0/M1 commands and no print is paused, execute
stop.g/sleep.g if they exist
Treat M25 within the file being printed the same as M226
Added additional simulation modes to help identify bottlenecks
Don't disable all interrupts when starting a new move, to reduce
interrupt latency so that we can still receive data from PanelDue
Moved some utility maths functions to CoreNG
2016-05-27 20:59:44 +01:00
David Crocker
0d47bd9546 Correct case of Pins_Duet.h 2016-05-08 19:06:45 +01:00
David Crocker
c1f5d919c2 Temporarily rename Pins_Duet.h to correct case 2016-05-08 19:05:51 +01:00
David Crocker
7c864d13e3 Version 1.12
Enhancements
=========
Added support for RTD temperature sensors
When cancelling a print, if cancel.g exists then run it instead of
turning heaters off
Improved file upload speed over the web interface
Chamber heater is now exempted from timeout
Pressure advance now reduces maximum extruder jerk setting by a smaller
amount when the extruder steps/mm is high
The Duet no longer reports itself as an Arduino Due and has its own
Windows driver
Added experimental "maximum average printing acceleration" feature
Try to improve speed of getting file information in Print Monitor

Bug fixes
======
Simulation mode was not working properly
External driver support code sometimes failed to enable the associated
drives
Fixed potential overflow if a user attempted to use non-existent driver
9 on a Duet 0.6
M408 status requests were not handled when in simulation mode
Removed hard coded PATH in project
2016-05-07 21:55:19 +01:00
David Crocker
1a0ce16128 Added support for PT100 and other RTDs
Added support for RTDs using the MAX31865 interface chip
2016-04-24 11:44:32 +01:00
David Crocker
1b16fc780c Changes for DuetNG 2016-04-15 21:47:13 +01:00
David Crocker
79828f9cd9 Version 1.11 release
Use updated CoreNG to fix incorrect extruder 1 motor current
Improved accuracy of setting extruder 1 motor current
2016-04-14 12:21:24 +01:00
David Crocker
f3a1b62c0a Version 1.11-beta1
Changed to CoreNG
Implemented chrishamm's latest Network and Webserver changes, including
Telnet streaming
Added S parameter to M997 command for DuetNG
Increased file read block size to 2K when getting file info
2016-04-10 21:50:16 +01:00
David Crocker
ee4f8fd3e5 Changes to use new core
Changed to use new core
Added build options for next generation Duet
When changing microstepping, update steps/mm automatically
2016-04-08 08:41:04 +01:00