Refactored printing to strings and web server json response handling in
preparation for adding support for LCD display via serial link
Added a timer to record how long block writes to SD card take
Fixed bug: if 5 point bed compansation was used then doing G32 more than
once would try to move the head off the edge of the bed unless the first
4 probe coordinates were reset between them.
Fixed bug: if the last command in a a macro file did not end in newline
then it might not be fully executed
Bug fix: potential array underrun in Gcodes::Pop()
Reduced Z dive height back to 5mm
M563 command extended to allow the tool number origin to be adjusted. If
there is no P parameter in the command then the S parameter specifies an
offset to be added to tool numbers in T, G10, M104 and M109 commands.
This is so that multi-media gcode files generated by slic3r can be
printed without having to edit all the tool numbers in the gcode file
first. This extension is intended to be temporary, until slicer provides
a mechanism for specifying the tool numbers. A separate offset is
maintained for each data source (USB, web or SD card) and the offset for
data from the SD card is reset to zero when a new file is started. To
use this facility to print slic3r multi-media gcode files, add M563 S1
to your start gcode.
M104 and M109 commands now accept an optional T parameter to specify the
tool number, as generated by slic3r in multi-media gcode files.
Movement code from RepRapPro's dev branch incorporated, including
5-point manual or automatic bed compensation mechanism.
Heater status (off/standby/on) is included in the status poll response
for the web interface. This will be used in a future version of the web
interface.
Incorporated code from RepRapPro dev branch to allow many more
M-commands to return values as well as set them.
Incorporated code from RepRapPro dev branch to implement the M119 and
M135 commands. There is currently a bug in the M135 (set heat sample
interval) command, which means that if you change the interval from its
default value of 0.5 seconds then you need to adjust the I parameter by
the same ratio and the D parameter by the inverse ratio.
Extrusion totals are reset to zero when starting a new print from SD
card.
M301 and M304 commands to set PID parameters now take an additional S
parameter. This allows for variations in cartridge heater power and
supply voltage to be taken into account more easily.
Temperature errors are reported to the web server as well as to USB.
The Heat section of the M122 diagnostics report now shows the
accumulated PID I-term.
G90 and G91 commands now affect only the the axes, not the extruders.
Bug fix: numerous calls to strncat were being made with a 'nchars'
parameter that was larger than space available in the destination
buffer.
Bug fix: print moves received just prior to an M109 or M190 command were
not executed until after the heater had reached temperature instead of
before.
Bug fix: using G10 to set oly the active temperature caused the standby
temperature to be set to an undefined value, and vice versa
G10 can now be used to retrieve the active and standby temperatures as
well as set them
Bug fix: I and D parameters were set to incorrect values when the M301
and M304 commands were used. They also reported the incorrect values.
New T parameter added to M301 and M304 commands, to allow the I term to
be preset to a suitable value when PID kicks in
Adjusted default PID parameters for lower overshoot and less oscillation
Bug fix: when axis or bed compensation was enabled a homing move to seek
for one endstop could be prematurely terminated by another endstop
M122 command only outputs LWIP stats if debug is enabled. Prevents a
hang if no UDB cable is connected when M122 is executed.
Bug fix: when resetting, the heaters used to power up for a short time
M0 and M1 commands now turn the heaters off instead of to standby
Web server status poll response now includes the selected tool number
Fixed M122 so that diagnostics are sent to the web interface as well as
USB
Fixed M220 command to respond to speed change requests faster
Count the number of active extruders and heaters, and only send their
values to the web interface, subject to a minimum of 2 heaters and 1
extruder
1. Reworked network layer to be more robust in the presence of network
errors (hopefully). In particular, don't release transmit buffers if
they might still be needed to retry sending data because the ACK got
lost.
2. Fixed bug whereby fileinfo command looked for the print height and
filament used if the extensio was .gcode or .gc or .gco but not if it
was .g.
3. When the M25 (pause print) command is received, pause the current
gcode so that commands such as M116 (wait for temperatures) can be
interrupted.
Added new request code rr_data for file uploading, and made other
changes to improve file upload speed.
Implemented S parameter to M208 command, to allow the negative limits of
axes to be set. Also reports current limits of no X/Y/Z parameter.
Reduced max reported free buffer size to 950 bytes to avoid problems
with file upload from Windows 8.1.
Reduced block read size when retrieving file info to work around an
intermittent bug that causes the SDHC card/ FATfs stack to return data
from the wrong sector sometimes. Tidied up some other code.
/*Fixed to work with multiple concurrent extruder drives:
* Default or M160 S1 (set use only one extruder drive)
* "G1 En.n" adds the float n.n to the move buffer for the selected
head
* There is no change in behaviour for one extruder drive setups, or
multiple extruder
* setups where only one drive is used at any one time.
*
* M160 Sn (set to use "n" extruder drives) eg
* "M160 S3"
* "G1 En.n:m.m:o.o" adds the floats to the move buffer in the
following way:
* moveBuffer[AXES+selectedHead) = n.n
* moveBuffer[AXES+selectedHead+1) = m.m
* moveBuffer[AXES+selectedHead+2) = o.o
* so if selectedHead=0 move buffer ends up looking like this for a 5
extruder drive setup:
* {x.x, y.y, z.z, n.n, m.m, o.o, 0.0,0.0, f.f}
* where x,y,z are the axes and f is the feedrate.
* If selected head > 0 then there is the possibility that more drives
can be set than
* exist, in that case the last values are discarded e.g:
* "T3"
* "M160 S3"
* "G1 En.n:m.m:o.o"
* would leave the move buffer on a 4 extruder drive setup looking
like this:
* {x.x, y.y, z.z, 0.0, 0.0, 0.0, n.n,m.m, f.f}
*/
Fixed bug introduced at version 057o-dc42 that broke the G32 bed
compensation. Added the Z heights of the bed compensation points to the
information displayed by M111 S2. Simplified the code that does
Z-probing in fast and slow stages. Added function sncatf and used it to
simplify the code in several places.
Changed the step interrupt service routine to use the average step size
when calculating the step interval, instead of the actual step size
which depend son whether X and Y are moving simultaneously. This should
give smoother movement, because from an inertial point of view the axes
are independent. It also fixes a bug whereby the accelerations were
incorrectly calculated, because DDA::AccelerationCalculation assumes a
uniform step size directly from start point to end point, whereas the
ISR was assuming a zigzag path. Also fixed bug with resetting the
minimum z-probe value seen when using an ultrasonic transducer in
differential mode.
1. Fixed bug whereby the first XY move after a Z move would often be at
a speed much higher than requested.
2. Added support for direct-mode ultrasonic sensor using command M558
P3. Command M558 P4 selects differential-mode ultrasonic sensor.
3. Changed temperature parameter in G31 command from T to S.
1. Fixed bug introduced at version 57r whereby axis travel limits were
not applied properly.
2. Increased maximum travel on 2nd phase of Z-probing from 1mm to 10mm
3. Added parameters R (thermistor 25C resistance) and B (thermistor
beta) to M301 command
4. Added support for M304 command with same parameters as M301 command
5. PID and thermistor parameters are now saved to flash memory
This will allow for multi extruder printing support in future pull
requests. It works fine for single extruder setups as well as the
selected head is always E0.
1. Z-probing is now done in two stages: a fast stage at the configured
home feed rate until within 10% of the target value, then a slow stage
at 20% of that feed rate.
2. Provisional support for ultrasonic Z-probe.
3. Added calibration temperature and height temperature coefficient to Z
probe parameters.
4. Z-probe parameters and Z-probe type are now saved to flash memory so
that they survive power-off and reset cycles. Separate parameters are
retained for IR and ultrasonic probes in case both are fitted.
5. Fixed issue with doing slow Z-moves immediately after Z-homing or
probing.
1. G92 with a Z value now sets exactly that Z value even if bed
compensation is in effect.
2. If G32 is run before the Z axis is homed, the first bed probe in the
G32 sequence homes the Z axiws.
Fixed problem whereby when printing in thin layers, the z-axis stepper
would try to move too fast, resulting in missed steps. This was because
the lookahead code was setting incorrect z-move velocities when a Z-move
was preceded by an extruder-only move.
Fixed printing over USB and via HTTP so that it uses the same lookahead
mechanism as for printing from SD provided the data arrives fast enough.
Added an incoming buffer for data arriving from USB. NOTE: Pronterface
needs to be patched to send the data fast enough for this to work well.
Also changed signatures of some member functions to be const-correct