1. Fixed variable name of extrusion factors in JSON status response
2. Fixed bug: changing heat sample interval no longer messes up I and D
pid factors.
3. Ensure that name of file being printed is null-terminated.
4. Removed redundant function SetStepHypotenuse.
Refactored printing to strings and web server json response handling in
preparation for adding support for LCD display via serial link
Added a timer to record how long block writes to SD card take
Fixed bug: if 5 point bed compansation was used then doing G32 more than
once would try to move the head off the edge of the bed unless the first
4 probe coordinates were reset between them.
Fixed bug: if the last command in a a macro file did not end in newline
then it might not be fully executed
Bug fix: potential array underrun in Gcodes::Pop()
Reduced Z dive height back to 5mm
M563 command extended to allow the tool number origin to be adjusted. If
there is no P parameter in the command then the S parameter specifies an
offset to be added to tool numbers in T, G10, M104 and M109 commands.
This is so that multi-media gcode files generated by slic3r can be
printed without having to edit all the tool numbers in the gcode file
first. This extension is intended to be temporary, until slicer provides
a mechanism for specifying the tool numbers. A separate offset is
maintained for each data source (USB, web or SD card) and the offset for
data from the SD card is reset to zero when a new file is started. To
use this facility to print slic3r multi-media gcode files, add M563 S1
to your start gcode.
M104 and M109 commands now accept an optional T parameter to specify the
tool number, as generated by slic3r in multi-media gcode files.
Movement code from RepRapPro's dev branch incorporated, including
5-point manual or automatic bed compensation mechanism.
Heater status (off/standby/on) is included in the status poll response
for the web interface. This will be used in a future version of the web
interface.
Incorporated code from RepRapPro dev branch to allow many more
M-commands to return values as well as set them.
Incorporated code from RepRapPro dev branch to implement the M119 and
M135 commands. There is currently a bug in the M135 (set heat sample
interval) command, which means that if you change the interval from its
default value of 0.5 seconds then you need to adjust the I parameter by
the same ratio and the D parameter by the inverse ratio.
Extrusion totals are reset to zero when starting a new print from SD
card.
M301 and M304 commands to set PID parameters now take an additional S
parameter. This allows for variations in cartridge heater power and
supply voltage to be taken into account more easily.
Temperature errors are reported to the web server as well as to USB.
The Heat section of the M122 diagnostics report now shows the
accumulated PID I-term.
G90 and G91 commands now affect only the the axes, not the extruders.
Bug fix: numerous calls to strncat were being made with a 'nchars'
parameter that was larger than space available in the destination
buffer.
Bug fix: print moves received just prior to an M109 or M190 command were
not executed until after the heater had reached temperature instead of
before.
Bug fix: using G10 to set oly the active temperature caused the standby
temperature to be set to an undefined value, and vice versa
G10 can now be used to retrieve the active and standby temperatures as
well as set them
Bug fix: I and D parameters were set to incorrect values when the M301
and M304 commands were used. They also reported the incorrect values.
New T parameter added to M301 and M304 commands, to allow the I term to
be preset to a suitable value when PID kicks in
Adjusted default PID parameters for lower overshoot and less oscillation
Bug fix: when axis or bed compensation was enabled a homing move to seek
for one endstop could be prematurely terminated by another endstop
M122 command only outputs LWIP stats if debug is enabled. Prevents a
hang if no UDB cable is connected when M122 is executed.
Bug fix: when resetting, the heaters used to power up for a short time
M0 and M1 commands now turn the heaters off instead of to standby
Web server status poll response now includes the selected tool number
Added new request code rr_data for file uploading, and made other
changes to improve file upload speed.
Implemented S parameter to M208 command, to allow the negative limits of
axes to be set. Also reports current limits of no X/Y/Z parameter.
Reduced max reported free buffer size to 950 bytes to avoid problems
with file upload from Windows 8.1.
Fixed bug introduced at version 057o-dc42 that broke the G32 bed
compensation. Added the Z heights of the bed compensation points to the
information displayed by M111 S2. Simplified the code that does
Z-probing in fast and slow stages. Added function sncatf and used it to
simplify the code in several places.
1. Fixed bug whereby the first XY move after a Z move would often be at
a speed much higher than requested.
2. Added support for direct-mode ultrasonic sensor using command M558
P3. Command M558 P4 selects differential-mode ultrasonic sensor.
3. Changed temperature parameter in G31 command from T to S.
Tidied up axis homing tracking.
When checking endstops, wait for move to complete before accepting
further moves, otherwise subsequent moves use the wrong coordinates.
Temperatures and Z probes are now monitored continuously using a tick
interrupt to kick off ADC conversions. ADC is now run in 12-bit mode.
Thermistor readings are passed through averaging filters. Thermistors
are monitored for overheat conditions and bad readings in the tick ISR
and the appropriate heater is turned off (useful because the main loop
sometimes gets suspended while trying to do USB communication).
Use watchdog timer to monitor the tick interrupt - needs patch to
Arduino Due core library. Add facility to test watchdog timer (M111
S1001). Added an error status word to record that errors have occurred
(e.g. over-temperature).
M111 command changes so that S0 turns debug off, S1 turns debug on, S2
reports free memory - also now reports the type of the last restart and
the error status word. Fixed problem whereby M111 debug reports were not
sent to the web interface.
Implemented M999 command, which resets the Duet.
Removed an unused variable.
Changed some more "char*" to "const char*".
Changed extruder PID parameters and added more explanation for them.
Fixed a random hang after z-homing in the previous release. Also make Z
probe temperature coefficient default to zero always, and Z probe
calibration temperature default to current bed temperature always.
1. Z-probing is now done in two stages: a fast stage at the configured
home feed rate until within 10% of the target value, then a slow stage
at 20% of that feed rate.
2. Provisional support for ultrasonic Z-probe.
3. Added calibration temperature and height temperature coefficient to Z
probe parameters.
4. Z-probe parameters and Z-probe type are now saved to flash memory so
that they survive power-off and reset cycles. Separate parameters are
retained for IR and ultrasonic probes in case both are fitted.
5. Fixed issue with doing slow Z-moves immediately after Z-homing or
probing.
1. G92 with a Z value now sets exactly that Z value even if bed
compensation is in effect.
2. If G32 is run before the Z axis is homed, the first bed probe in the
G32 sequence homes the Z axiws.
track up the low-precision slope of the IR probe before measuring down
the high-precision slope near 0 mm. But this means that the probe has to
be set only a fraction of a mm higher than the nozzle itself. Also (at
the moment for safety) the code thinks Z = 0 occurs when it is actually
0.2mm. This is easy to fix when the rest is reliable.