Updated WHATS_NEW.md for release 1.18
This commit is contained in:
parent
d47cc13765
commit
1be6e8d7d8
1 changed files with 7 additions and 2 deletions
|
@ -1,8 +1,8 @@
|
||||||
Summary of important changes in recent versions
|
Summary of important changes in recent versions
|
||||||
===============================================
|
===============================================
|
||||||
|
|
||||||
Version 1.18RC1
|
Version 1.18
|
||||||
===============
|
============
|
||||||
|
|
||||||
New features:
|
New features:
|
||||||
- First official release for Duet Ethernet
|
- First official release for Duet Ethernet
|
||||||
|
@ -22,6 +22,10 @@ New features:
|
||||||
- Live coordinates are now reported to 3 decimal places instead of 2
|
- Live coordinates are now reported to 3 decimal places instead of 2
|
||||||
- When using a Z probe type other than 2, the probe output is sampled every 1ms instead of every 2ms for faster response
|
- When using a Z probe type other than 2, the probe output is sampled every 1ms instead of every 2ms for faster response
|
||||||
- PanelDue status responses continue to be sent while executing M109/116/190/191 commands
|
- PanelDue status responses continue to be sent while executing M109/116/190/191 commands
|
||||||
|
- Increased maximum permitted motor current on TMC2660 drivers to 2.4A
|
||||||
|
- Improved error messages when a M303 command has an out-of-range parameter
|
||||||
|
- We now use a USB VID/PID allocated to us instead oif Atmel's CDC example ones
|
||||||
|
- The Windows device driver now supports the Bossa Program Port, so you can now use bossac even if you don't have the Atmel or Arduino device driver for it installed
|
||||||
|
|
||||||
Bug fixes:
|
Bug fixes:
|
||||||
- Fixed issue with loading height map file when the number of probe points along the X axis is large
|
- Fixed issue with loading height map file when the number of probe points along the X axis is large
|
||||||
|
@ -40,6 +44,7 @@ Known issues
|
||||||
- FTP on the Duet Ethernet cannot be used to do file transfers
|
- FTP on the Duet Ethernet cannot be used to do file transfers
|
||||||
|
|
||||||
Upgrade notes
|
Upgrade notes
|
||||||
|
- If you connect via USB from a Windows PC you should install the updated device driver in the Drivers folder of this repository
|
||||||
- If you use the M552 R parameter to change the HTTP port number on a wired Duet, you will need to use M586 instead
|
- If you use the M552 R parameter to change the HTTP port number on a wired Duet, you will need to use M586 instead
|
||||||
- If you use FTP or Telnet on a wired Duet, you will need to enable them using M586
|
- If you use FTP or Telnet on a wired Duet, you will need to enable them using M586
|
||||||
- It is recommended that you re-run heater auto tuning when upgrading to 1.18 from an earlier release
|
- It is recommended that you re-run heater auto tuning when upgrading to 1.18 from an earlier release
|
||||||
|
|
Reference in a new issue